FLEXCOMMAND - Surge Low Level Delay

Sets how many seconds the surge hopper's low level status is held back, so the hopper finishes emptying before the next order uses it.

Applies To

  • Dry tower systems with a surge hopper

Overview

The surge hopper's low level sensor trips while the last of the product is still draining out. The Surge Low Level Delay adds a number of seconds before that status is reported to the loadout application, so the hopper is empty by the time the next order is allowed to use it. This keeps product from one order out of the next.

Like other settings on the Dispenser Settings screen, the Surge Low Level Delay is usually configured during commissioning.

Setting the Delay

On the FLEXCOMMAND HMI, the technician opens "Surge Settings" > "Dispenser Settings" and enters the number of seconds in "Surge Low Level Delay".